Add to Basket Transcutaneous Jaundice Detector (KJ-8000)

Model NO.: KJ-8000
Trademark: kejian
Product Description

±KJ-8000 Transcutaneous Jaundice Detector

Overview

The high bilirubin- emia is the ordinary diseases for newborns, the macroscopical Jaundice will occur to above 50% term infant and 80% premature. Serious one can effect newborns'intelligence development, jaundice of newborn is the main diseases for newborns. High incidence of a disease, kernicterus is the main reason for infant's cerebral palsy and death caused by grave jaundice of newborn(high bilirubin- emia)
Hereby clinically, it needs dynamic observation to newborns jaundice. In order to discover and treatment early. But reduplicate blood sampling, not only takes pain to newborns, but also add the staff's workload and difficulities.

Diagnostic standard for pathological jaundice
1. The Jaundice appears within 24 hours after born, serum bilirubin concentration for term infant >6mg/dl; Serum bilirubin concentration>9mg/dl within 24-48 hours; Serum bilirubin concentration>12.9mg/dl; Premature are 8,12,15mg/dl.
Serum bilirubin concentration for term infant >220.6umol/l(12.9mg/dl)
Serum bilirubin concentration for premature >255umol/l(5mg/dl)

2. Serum conjugative bilirubin concentration >34umol/l(2mg/dl)
3. Serum bilirubin rising >85umol/l(5mg/dl)for every day.
4. The Jaundice lasts for long time, exceed 2-4 weeks, or more serious progressively.
5. Appears not early but always can not be cured, or reoccurred after fadeaway
Function features:
1. KJ-8000 is mainly used to measure transcutaneous bilirubin value relating to serum bilirubin value of newborns and infants. It is a kind of filtering medical testing instrument that blood sampling is not necessary and there is no pain or bacteria infection.
2. Displayed unit: Mg/dl, umol/l, no unit(bilirubin) optional
3. No blood sampling, no pain, no infection, small volume, light weight, easy for carrying, direct reading, no conversion, endurable battery, exact, quick, intuitionistic, no wound, intelligentized, miniaturization, convenient, stable, reliable.
Technical index
1. Checking method: Reflecting light
2. Display: Three digits LCD display on the big screen. The wrong data can be alarmed and deleted. The unit can be switched between mg/dl,umol/l freely.
3. Lamp-house: Xenon flash light
4. Power: 4.8v rechargeable pile
5. Quick charge: Charging time 3 hours.
6. Measuring times: At least 500 times after charging.
7. Calibration function: Automatic
8. Calibration screen: Display "00.0" or"00.1"
9. Indication error: 0-15 is 1, 16-25 is ±1.5
10. Accuracy: ¡Ü 6% of the pre-set value
11. Repeatability: ¡Ü 3%
12. Prompt facility: When the battery voltage lower than 4.4V, appears symbol. Means the battery needs charge.
13. Average measurement function: 2~5 times can be set

Click here to send inquiry
 